Analytical performance of some methods for the determination of trace elements in lichens used as air quality assessment

Thumbnail
View/Open
Analytical performance of some methods for the determination of trace elements in lichens used as air quality assessment.pdf (462.3Kb)
Date
2009
Author
Montero, A
Estévez, J.
Padilla, R.
López, D.
Metadata
Show full item record
Abstract
Se realizó un estudio en la ciudad de La Habana utilizando liquen como monitor de la contaminación del aire. La concentración de varios elementos traza (Ca, Mn, Fe, Ni, Cu, Zn, Sr, Cd, Pb) en un total de 225 muestras se determinó mediante Fluorescencia de Rayos X de Reflexión Total (TRXRF), Espectroscopía de Absorción Atómica de Llama (FAAS) y voltametría de extracción anódica (ASV). Además, se analizaron varios materiales de referencia biológicos certificados (CRM) para evaluar el rendimiento analítico de los resultados. En general, se encontró un acuerdo relativamente bueno entre las técnicas. No se encontraron diferencias significativas entre los resultados obtenidos y los valores de referencia certificados. A study was carried out in Havana City using lichen as monitor of air pollution. The concentration of several trace elements (Ca, Mn, Fe, Ni, Cu, Zn, Sr, Cd, Pb) in a total of 225 samples was determined by Total Reflection X Ray Fluorescence (TRXRF), Flame Atomic Absorption Spectroscopy (FAAS) and Anodic Stripping Voltammetry (ASV). In addition several Biological Certified Reference Materials (CRM’s) were analyzed in order to assess the analytical performance of the results. In general a relatively good agreement was found among the techniques. No significant differences were found between the obtained results and the certified reference values.
URI
http://repositorio.geotech.cu/xmlui/handle/1234/2832
Collections
  • Proyecto OP-15 Documentos de Referencia [624]

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV